About 1,144,779 results (5,299 milliseconds)

How to test an RV air conditioner's starting capacitor

https://groups.google.com/g/heatsynclabs/c/pAiAFwKbT6k
Fair warning don't expect it to be usable after but if it's bad it won't do anything and you have your answer. FYI if a fan or compressor are replaced you ...

TXV Repacement $1100???

https://groups.google.com/g/alt.hvac/c/MUkf0CooqZg
the blower. Are you located in a high humid climate? If the compressor is getting ... Changing the coil in this case when only the TXV is bad is >> criminal ...

Holden Astra - Air Conditioner Problems - Regas, or Compressor

https://groups.google.com/g/aus.cars/c/eAKrsXRO2RY
If you do, it's almost certainly the compressor clutch coil because the BCM is requesting the compressor to cut in which indicates that the pressures and ...

Payne Air Conditioning Units...any good?

https://groups.google.com/g/alt.hvac/c/oWc72LnxP6I
idea of whether this company has a good/bad history, or if certain units should ... have a good excuse, like a bad heat exchanger or compressor, I'll replace it ...

Only 1/3 evaporator coil is cold

https://groups.google.com/g/alt.hvac/c/VCRfGFqjT38
to the room and make sure the room is inflated to 14.7 PSI. More seriously, tell us about this "moving the AC" bit? ... > It is a compressor fault, weak pumping ( ...

Bryant Heat-Pump < 3 yrs old with bad TXV and Access Port?

https://groups.google.com/g/alt.hvac/c/9cWrCiasSWI
Jun 24, 2003 ... 3) If both access ports are bad then it probably was overheated. ... Im not sure what to tell you if you are staying with the same company.

Re: What Causes Compressor Leads to Burn Off of Terminals?

https://groups.google.com/g/alt.hvac/c/2NySHs5ARMI
If you think his compressor is bad, why don't you mention that? Dimwit (at least I admit it) sprinkler system armed. "Al Moran" <[email protected]> wrote ...

Home coil / condenser mismatch question.

https://groups.google.com/g/alt.hvac/c/3vIGxKsKCuA
Mar 12, 1998 ... Can someone tell me what this means? I have a 42,000 btu evaporator coil on my new Lennox 100,000 WhisperHeat furnace that is mated to a

Contactor replacement - was I robbed?

https://groups.google.com/g/alt.hvac/c/9sqk5UwEFzY
wire. Helpful hints, make sure the condenser is always clean, check the bleed resistor if there is a start capacitor, install a time delay relay or ...

gurgling sound in liquid line

https://groups.google.com/g/alt.hvac/c/EOuRKRnW9ys
Non-condensables get trapped in the condenser coil by the liquid seal at the condenser outlet when the system is running. Can anyone explain to me how non ...

Local News: Menlo Park moving to ban installation of new gas ...

http://feedproxy.google.com/~r/PostsFromPlcHvacLocksmith/~3/TZSIXK3l6FY/
Aug 20, 2021 ... ... Air Conditioning Technicians. If you are not ... bad for the lowest house on that main ... compressor and motors.) Heat pump systems ...

Is a refrigerant leak around the Schrader valve "normal"?

https://groups.google.com/g/alt.hvac/c/Q_Xu5XJ8ego
> Recommends a new evaporator coil unit inside. > Unit is 11 years old. Only problem before now was capacitor when under > warranty when a couple ...

Coleman Packaged Evaporator leaks

https://groups.google.com/g/alt.hvac/c/CtQ75ALe-a8
Bad compressor and possible ... If you learned to speak in full sentences. ... I think if there are problems with coils and after a coil is replaced then

compressor runs backwards??

https://groups.google.com/g/alt.hvac/c/pF1RPIf42Gk
Strecker , If a compressor is ... Valves can cause strange symptoms when they go bad. ... If the strips are before the coil in a heat pump, the head pressure

wires to capacitor on YORK AC unit are burned and melted

https://groups.google.com/g/alt.home.repair/c/e4MDCobVXho
compressor, has the coil ... The pictures aren't good enough to tell if the upper terminal connection ... > points of the contactor for to see if or how bad they ...

Trane Heat Pump: Permanent 24v to Reversing Solenoid?

https://groups.google.com/g/alt.hvac/c/2m49tVa_ZoQ
>problem that will RUIN your compressor if not addressed. It is only ... What, if the coil burns up ??? Err...depends ... > 'cheaper regular AC only compressors' ( ...

Holden Astra air-con clutch fix

https://groups.google.com/g/aus.cars/c/aCFKHkomN-o
Thanks but I found it on the interweb and had a go at it today. It's got a 187 thermal fuse on the inside (compressor side) of the coil that had blown. It's a ...

Air Conditioning

https://groups.google.com/g/beneteau-owners/c/NzZI8CltqwQ
Their coil is titanium, their compressor is shielded, they are so quite you can't tell is running. ... if the doors are closed. ) If you latch the ... Bad link, try.

Checking a Condenser Fan Motor Amp draw.

https://groups.google.com/g/alt.hvac/c/tNwrCfo_tbo
Check to seek if the blade hub is level (as bent ... >Reversing valve coil, and every part on the condenser except the compressor ... heat due to low airflow ( ...