About 1,334,077 results (3,658 milliseconds)

EMT electrical conduit -- how many NM wires?

https://groups.google.com/g/alt.home.repair/c/j4GGHXli-eY
is fed inside of metal EMT conduit. I assume that the metal conduit is 1/2-inch (the outside diameter of the conduit is about 3/4-inch). I would like to add ...

How to the Optimize the Strength of a Geodesic Dome?

https://groups.google.com/g/geodesichelp/c/7cHKrCYexgM
Dec 22, 2016 ... Now deliberating which ought to be the stronger of the two. 4 frequency dome + 1 1/2 inch EMT conduit + 5 foot strut average (2 per 10ft ...

Fire Alarms Conduit size

https://groups.google.com/g/alt.security.alarms/c/S25xcSk38_M
You can use 1/2 " conduit for fire as long as you do not exceed the amount ... > > Many electricians tell me that the minimum EMT conduit size for fire > > ...

US4781847A - Aqueous lubricant - Google Patents

https://patents.google.com/patent/US4781847A/en
TABLE 1. Conduits Polyvinyl ... (PVC) conduit and a 2 inch inside diameter electrometallic conduit (EMT). A ...

Building 20' sliding pool poles out of EMT conduit (is it possible?)

https://groups.google.com/g/alt.home.repair/c/BSPRyQ29lSc/m/6DBC3YLzPhUJ
... outer sheath outside the steel EMT electrical conduit because it won't get ... One man can pick up an eight inch diameter pipe with reasonable effort. Suppose

WO2009032395A1 - Methods and systems for re-metallizing weld ...

https://patents.google.com/patent/WO2009032395A1/en
Mar 12, 2009 ... ... size conduit and increasing to about 0.266 inches for 6 inch trade size conduit. ... 1, wherein the zinc-coated steel conduit is electrical ...

Easiest way to enlarge an electrical knockout?

https://groups.google.com/g/alt.home.repair/c/J43DP_RuCRM
are sized for 1/2" conduit. I need a hole for 3/4" conduit to accomodate the ... > > falling inside the heater, or overshooting the size I need and making

US5661942A - Modular connector system for tubular structural ...

https://patents.google.com/patent/US5661942A/en
... 1, are sized with an outer diameter to receive the 2- inch members 4 thereover and an inner diameter to receive a 1.5-inch EMT conduit member therein. If ...

Recycled Recumbents! - Seat frame construction

https://sites.google.com/site/recycledrecumbents/seat-frame-construction
In this set of pictures, I am making 5 seats. You might be making only one. I suggest you cut 3 'blanks' at least from ½” EMT conduit – bend all three and you ...

US5342994A - Electrical connector for mounting to electrical ...

https://patents.google.com/patent/US5342994A/en
As a result of their extensive use, these enclosures have dimensions which are of a standard magnitude. Electrical wire conduit, i.e. flexible (flex), rigid or ...

US6904690B2 - Pipe size identifier and measuring tool - Google ...

https://patents.google.com/patent/US6904690B2/en
... conduits made from different materials have different outer diameters and different inner diameters. For example: a designated one-half (½) inch diameter pipe ...

Designing a dome optimized to be built from recycled plastic

https://groups.google.com/g/geodesichelp/c/-IL99subeYk/m/yMw38JtOAgAJ
... 1 inch nominal pvc or metal emt which has a 1.049 inside diameter. The 85 tubes could all be gathered into a bundle just 9 or 10 inches in diameter for carrying ...

Filling a PVC pipe to make a stronger outdoor shower rod. Need help.

https://groups.google.com/g/alt.home.repair/c/rDYEhidcOt8
on a 2" PVC insert a length of EMT / MEtal Electrical Conduit, Maybe 1/2", center it inside the PVC pipe and fill it up with expansion foam. It will be nice, ...

US7631434B1 - Plumb/level alignment gauge for aligning structural ...

https://patents.google.com/patent/US7631434B1/en
Dec 15, 2009 ... ... inch in diameter and slips over a ¾ inch outside diameter (O.D.) length of standard galvanized electrical conduit (EMT, or Electrical ...

Offset Pipe calculator - Apps on Google Play

https://play.google.com/store/apps/details?id=ru.sotnikov.offsetpipe
Pipe Offset Calculator is a construction calculator for the pipe industry, mechanical engineering, plumbing, oil and gas industry, pipeline installers, ...

CA2061525C - Quick connect fitting for electrical junction box ...

https://patents.google.com/patent/CA2061525C/en
The spring steel adaptor 20 of Figure 16 is typically .~38 inches in outer diameter measured across the flat surface of the spring. Across its diameter from one ...

Building TV Antenna - length chart needed

https://groups.google.com/g/sci.electronics.design/c/T2N_buV6XJo
several lengths of 1-1/4" EMT conduit. It sits about 5 feet above the ... Multiply that by 39.37 inches / meter and you have the wave length is 65.62 inches.

US8220332B1 - Conduit toner and detector - Google Patents

https://patents.google.com/patent/US8220332B1/en
Large diameter (more than two inches) conduit may be installed ... At one end of the conduit, the inside air is vacuumed while the opposite end ...

Conduit Filler - Apps on Google Play

https://play.google.com/store/apps/details?id=com.archalog.conduitfiller
Mar 4, 2025 ... The Conduit Filler is designed to help electrical tradespeople with their conduit fill calculations and with conduit sizing for various gage ...

MIL-HDBK-419A Grounding, Bonding, and Shielding for Electronic ...

https://groups.google.com/group/epc-school/attach/6c7f0e17b8c3f9a4/hdbk419a_vol2.pdf?part=0.1
Jan 21, 1982 ... The minimum sizes are 1.27 cm (1/2 inch) in diameter for solid ... of a Typical Building at 6 Feet Inside Outer Wall (1-12). Figure 1-82 ...